The purpose of the isolating amplifier Theta 60I is to electrically insolate input and output signals, respectively to amplify and / or change the signal level or type (current or voltage) of the input signals. Special Features: 252 standard input and output combinations selected by soldered jumpers User-specific input and / or output ranges Isolating amplifier with one input one or two electrically insulated outputs. Power supply 24…60VDC/AC or 85…230VDC / AC Electric Isolation between input, output and power supply, prevents falsified measurement due to spurious potentials. Flexibillity provided by more than 250 different input and output combinations selected by simply positioning soldered jumpers, help in reduced stocking. Processes unipolar/ bipolar and live zero signals provision for raising burden and signal conversion Green LED signals indicates device in operating condition. High Electrical Insulation between input and output – 2.3KV, and power supply versus all Other Circuits-3.7 KV Provision for either snapping the isolating amplifier on to top-hat rails or securing it with screw to a wall or panel.
  • Voltage: 85~230 V DC / AC,24~60 V DC / AC
  • Display: LED indication for power ON
  • IP: housing:IP 40,terminal:IP 20
  • Measuring Inputs:
  • DC Current: 0... 0.1 mA~0... 20 mA DC Voltage:0... 0.06 V~0... 40 V
  • Measuring outputs:
  • DC Currents: 0…20mA, 4…20mA, +20 mA
  • Operating temperature:
  • -25 ~ 55 °C

Electro Meter co.

Bornika Map
Show Map