Electrometer Trading Co. began its work with the mission to deliver Measuring Instrument equipment to the market at the highest possible quality and the most possible timely manner. We proudly represent world-class manufacturing companies such as 3M, Autonics, Cooper Bussmann, ERICO, Ferraz Shawmut, General Electric, Hioki, Ideal, legrand, Littlefuse, Lutron, Phillips, Schneider Electric, Siemens, Fluke, Yokogawa, Megger, Gossen GmbH, etc. Our branch in Carson, California began its work in 2007, at which, a combination of experienced industry veterans and young progressive forces have been working to provide our clients with the best possible support.

Electro Meter products
  • Alpha 10
  • Alpha 10 measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters. It measures electrical parameters like AC Voltage, AC Current, & many more.
  • Alpha 20
  • Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters. It measures electrical parameters like AC Voltage, AC Current, Frequency, Active, Reactive, Apparent Power, Import Export Energy & many more.
  • Alpha 30
  • Alpha 30 measures important electrical parameters like AC Voltage, AC Current, Frequency, Active, Reactive, Apparent Power, Import & Export Energy & many more.
  • Alpha 40
  • Alpha 40 measures important electrical parameters in 3 phase and single phase Network & replaces the multiple analog panel meters. It measures electrical parameters like Active / Reactive / Apparent energy & power as per models. The instrument has optional output as one pulse output for energy measurement. it is also applicable for Energy billing, Electrical load monitoring, Sub-metering, Genset, Test Benches and Laboratories.
  • Alpha 40D
  • Alpha 40D measures important electrical parameters like Active / Reactive / Apparent energy , power. The instrument has optional output as two pulse output for energy measurement. it is also applicable to Energy billing, Electrical load monitoring , Sub-metering Genset, Test Benches and Laboratories.
  • Alpha 45
  • Alpha 45 is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy with class 1.0 accuracy having auto-resetting 8 digit seven segment LED counter. The unit provides LED indication for healthy phase, load reverse current. The Alpha 45 is available in two version 3phase 4 wire / 3 wire unbalanced load and single phase and is ideal for secondary metering in industrial applications.
  • Alpha 50
  • Alpha 50 measures important electrical parameters in 3 phase and single phase Network & replaces the multiple analog panel meters. It measures electrical parameters like AC current, Voltage, frequency, active energy import & active energy export, Current Demand, kW Demand, kVA Demand and Max Current Demand, Max kW Demand and Max kVA Demand. The instrument has optional output as one pulse output or two pulse output for energy measurement.
  • Alpha 70
  • Alpha 70 is a compact, multi-function panel mount power quality monitor, which measures, calculates and displays major electrical parameters of three phase power system like voltage, current, active/fundamental reactive, apparent power and energy, individual harmonics, sags and swells.
  • ND20
  • ND20 Metering Network parameters such as Voltage,Current, Frequency, Ac􀀏tive power, Reac􀀏tive power, Apparent power, Power factor, cos φ, tg φ, φ, Imported acti􀀏ve energy and others.
  • N43
  • N43 is a rail mounted power Network meter that measuring Voltage, Current, Frequency, Acti􀀏ve power, Reacti􀀏ve power, Apparent power, Power factor, tg φ, acti􀀏ve energy and reacti􀀏ve energy.
  • Beta 10P,20P,30P,40P
  • The digital panel meter Beta P Series have been designed for industrial applications, which frequently require precise and on site adjustment of the display range.
  • Beta 50,60,70
  • Beta 50/60/70 have been designed for industrial applications, which frequently require precise and on-site adjustment of the display range. It can be used in industrial automation and for laboratory uses.
  • Beta 90
  • Beta 90 is designed for industrial applications, which frequently require precise, on-site adjustment of the display range. It can be used in industrial automation and for laboratory uses. It provides cost-effective solution for virtually all switchboard instruments.
  • Beta 90A,90B
  • Beta 90A / 90B is the digital panel meter designed for industrial applications, which frequently require precise, onsite adjustment of the display range.It can be used in industrial automation and for laboratory uses. It provides cost-effective solution for virtually all switchboard instruments.
  • Beta 90T
  • Beta 90T is the digital panel meter 48 x 96 mm size have been designed for industrial applications, which frequently require precise, on-site adjustment of the display range. It is basically used for temperature measurement.
  • Beta G1
  • Beta G1 have been designed for industrial applications, which frequently require precise and on-site adjustment of the display range. It can be used in industrial automation and for laboratory uses.
  • Beta Hz
  • Beta Hz has been designed for frequency measurement in industrial applications. Frequency measurement ranges available are 12…199.9 Hz and 12…500 Hz.
  • N30P
  • N30P is destined to measure: a.c. voltage, a.c. current, active, reactive and apparent power, cos φ, tg φ, φ, frequency, active, reactive and apparent energy, 15 min. active power, 10 min. voltage, 10 sec. frequency in single-phase power network
  • N30O
  • N30O is destined for the measurement of pulses, frequency, rotational speed, period and worktime. The meter has 2 counter inputs to co-operate with an encoder. The meter also counts the actual and total value.
  • Beta G2
  • Beta G2 have been designed for industrial applications, which frequently require precise and on-site adjustment of the display range. It can be used in industrial automation and for laboratory uses.
  • N30U
  • N30U is destined for the measurement of temperature, resistance and standard signals.
  • N27P
  • N27P is designed for direct or indirect measurement of 1-phase network parameters: U, I, f, P, Q, S, PF, tg φ, φ, Ep, Eq. N27P fulfills the requirements for devices mounted in standard modular switchgears.
  • NA3
  • These are the programmable meters with multicolour bargraph indicators NA3 is destined to measure and recording D.C. Current or D.C. Voltage, temperature, resistance and other non-electrical magnitudes like: level, flow, pressure, humidity
  • NA5
  • These are the programmable meters with multicolour bargraph indicators NA5 is destined to measure and recording d.c. current or d.c. voltage, temperature, resistance and other non-electrical magnitudes like: level, flow, pressure, humidity
  • NA6
  • These are the programmable meters with multicolour bargraph indicators NA6 is destined to measure and recording d.c. current or d.c. voltage, temperature, resistance and other non-electrical magnitudes like: level, flow, pressure, humidity
  • N30H
  • N30H is destined for the measurement of d.c. current and d.c. voltage up to 5 A and 600 V.
  • Theta 10A,10V
  • It is the transducer that converts a sinusoidal AC Current or AC Voltage into a load independent DC Current or a load independent DC Voltage proportional to the measured value.
  • Theta 20A,20V
  • It is used to measure and convert AC Voltage or Current input into a load independent DC current or voltage output signal.
  • Theta 30P
  • It is a compact, multi-function panel mount power quality monitor, which measures, calculates and displays major electrical parameters of three phase power system
  • Theta 40
  • This series of multi-transducers simultaneously measure several variables of an electric power system and process them to produce 2 or 3 or 4 analogue output signals. 2 or 4 digital outputs are available for signaling limits or power metering. For two of the limit outputs up to 3 measurands can be logically combined.
  • Theta 60R
  • The transmitter Theta 60R Converts the input variable-a signal from a resistance thermometer PT-100- to a temperature linear output signal.
  • P30O
  • P30O, The transducers of pulses, Frequency, Turns, Operating time
  • P30U
  • P30U (Transducer of Temperature & Standard Signals)
  • P43
  • It Programmable Transducer of 3-Phase Power Network Parameters
  • P18D
  • It is the device destined for the continuous measurement and conversion of relative humidity and ambient temperature into a digital or analog standard signal. Additionally P18D transducer is equipped in LCD screen.
  • P19
  • It is the Temperature & Humidity Transducer
  • Theta Hz
  • The transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
  • Theta 50
  • Theta 50 is used to electrically isolate input, outputs & power supply. It is all requirements & regulations concerning electromagnetic compatibility (EMC) & safety (IEC 61326-1 & IEC 61010-1-2010)
  • Theta 60I
  • The purpose of the isolating amplifier Theta 60I is to electrically insolate input and output signals, respectively to amplify and / or change the signal level or type (current or voltage) of the input signals.
  • Theta 60M
  • The universal theta 60M convert the input variable – a DC current or voltage , or a signal from a thermocouple,resistance thermometr, remote sensor or potentiometer – to a proportional analogue outpur signal. The analogue output signal is either an impressed current or superimposed voltage which is processed by other devices for purpose of displaying, recording, and/or regulating a constant. A considerable number of measuring ranges including bipolar or spread ranges are available.
  • Omega 10
  • Omega Series is a range of Split core current transformers that offers a cost effective and efficient method by which the current can be measured without the need to break the conductor, thereby reducing the installation and commissioning time.
  • Omega 20
  • The Omega 20 (TW - CT's) series consists of round type CTs are housed in robust case with classical finish. The case is made of polycarbonate, which is flame retardant and non-drip and confirms to international regulations UL 94 V-0
  • Omega 30
  • The ANSI Metering Class transformers are intended for power monitoring applications where high accuracy and minimum phase angle error are required. They are specially designed to be compliant with relevant ANSI standards.
  • Gamma 10
  • It is Analog Digital Multimeter which measures VAC, VDC, VAC+DC,Frequency, mA DC, mA (AC+DC), Resistance, continuity, Diode, Farad, AC current measurement
  • Gamma 20
  • Gamma 20 is 5 ¾ digit and 309999 counts High Precision Multimeter ( V A Ohm Hz F °C Diode) Direct Amp. measurement upto 10A, Triple display of V, Hz or V and Min/Max. RMS with distorted wave, Continuity, Dutycycle, DataHold, Auto/Manual range, °C(PT100/1000), overload warning, Auto off. Cat III/IV
  • Gamma 12
  • It is Analog Digital Multimeter which measures VAC, VDC, VAC+DC,Frequency, mA DC, mA (AC+DC), Resistance, continuity, Diode, Farad, AC current measurement.
  • Gamma 30
  • Gamma 30 Adapter has LCD-segment-display unit and 4 keys. Nearly all parameters can be set manually or by means of the interface via a PC. In On-line mode (on address) the adapter transfers data received from multi meter (without storing in its internal memory) to a PC over RS-232 serial interface.It is a Data logging, Data processing, Data analysis, Data recording, Y(t) recorder and XY recorder.
  • Gamma 40
  • digital multimeters are suited for universal, general applications in the electrical and electronics radio and television service, training and education
  • Gamma 50
  • These digital multimeters are suited for universal, general applications in the electrical and electronics radio and television service, training and education
  • Gamma 60
  • These digital multimeters are suited for universal, general applications in the electrical and electronics radio and television service, training and education
  • Gamma 70
  • These digital multimeters are suited for universal, general applications in the electrical and electronics radio and television service, training and education
  • Delta 1000
  • It measures important electrical parameters like AC Current (TRMS), DC Current,AC Voltage(TRMS), and DC Voltage. It also features Capacitance, Ohm & Continuity, frequency, and Duty cycle and temperature measurement
  • Delta 300
  • It measures important electrical parameters like AC Current (TRMS), DC Current,AC Voltage(TRMS), and DC Voltage. It also features Capacitance, Ohm & Continuity, frequency, and Duty cycle and temperature measurement
  • Delta Clip A
  • Delta Clip A measures current without interrupting the conducting line. They are used for electrically isolated measurement of alternating current within a broad range, without interrupting the current conducting cable and bus bars
  • Delta Clip B
  • Delta Clip B measures current without interrupting the conducting line. They are used for electrically isolated measurement of alternating current within a broad range, without interrupting the current conducting cable and bus bars
  • Zeta 20
  • Analog digital Insulation & continuity tester for measure of 10Kohm-2Gohm with selectable test voltage upto 1000V. LR measurement from 0.01-99.9 ohm & upto 600V AC/DC. Storage of Min, Max & last 50 readings. Preselectable measurement time, stop watch, fuse blow, auto power off
  • Zeta 30
  • It is Analog Digital Multimeter with insulation resistance measurement , which measures VAC, VDC, VAC+DC,Frequency, mA DC, mA AC+DC,Resistance, continuity, Diode, Farad, AC current measurement with clip-on sensor and insulation resistance measurement.
  • Zeta 50/50K
  • Zeta 50 / 50K Is used for the non-destructive measurement of insulation resistance in electrical systems, at machines, transformers and cables.
  • KD7
  • Iota series recorders are designed for measurement and recording of process and major electrical parameters which may be critical for the system and affect the process performance. Data recorded can be retrieved for after fault analysis. The recorders have facility to intake data either from temperature sensors, analog signals from the process transmitters (used for flow, pressure, humidity, etc.) The recorders are facilitated with analog channels & Modbus channels to ease the recording of data.
  • SM61
  • Iota series converters & recorders are designed for measurement and recording of process and major electrical parameters which may be critical for the system and affect the process performance. Data recorded can be retrieved for after fault analysis. The recorders have facility to intake data either from temperature sensors, analog signals from the process transmitters (used for flow, pressure, humidity, etc.) The recorders are facilitated with analog channels & Modbus channels to ease the recording of data
  • N30B
  • The digital panel recorder N30B is destined to data readout and recording from devices with RS-485 interface and Modbus RTU protocol
  • PD8
  • The PD8 converter allows to transmit data to the master devices through the computer network of Ethernet type, to devices equipped with the RS-485 and RS-232 interface
  • RE72
  • These Controllers are designed for precise measurement and control of sophisticated systems where precise and accurate measurement & controlling actions are required. Controllers are available with wide range of sensor inputs, analog signals & resistance input. Available in single and dual input channels with additional auxiliary input facility
  • RE92
  • These Controllers are designed for precise measurement and control of sophisticated systems where precise and accurate measurement & controlling actions are required. Controllers are available with wide range of sensor inputs, analog signals & resistance input. Available in single and dual input channels with additional auxiliary input facility
  • Sigma Series DE Meter
  • The moving iron panel meters, DE 48/72/96/144 housed in moulded polycarbonate cases are suitable for the measurement of AC currents for frequency range of 15...400Hz and voltages in the frequency range of 15...100Hz
  • Sigma Series DS Meter
  • The moving coil panel meters, DS 48/72/96/144 housed in moulded polycarbonate cases are suitable for the measurement of DC currents and voltages.
  • Sigma Series DG Meter
  • The moving coil, rectifier meters, DG 48/72/96/144 housed in moulded polycarbonate cases are suitable for the measurement of AC currents and voltages
  • Anush Series
  • The Anush range of analog panel meters offers accurate measurement and indication of most electrical and electronic parameters in industry standard sizes. This innovative design features a detachable lower fascia plat which allows the flexibility of either surface or window mounting. The fascia is simply unclipped to achieve the completely flush panel appearance of panel window mounting.
  • Vista Series
  • The Vista Series of analog panel meters offers accurate measurement and indication of most electrical and electronic parameters in industry as per industrial standard case size.
  • Sigma Series DSL Meter
  • The moving coil panel meters, DSL 48/72/96/144 housed in moulded pol carbonate cases are suitable or the measurement o DC currents and voltages. These instruments Offer several advantages in switchboards and Generating Set Panels. Number of meters can be mounted in a Panel Cut out (Mosaic mounting). Front glass, Bezel & Dial can be easily replaced.
  • Sigma Series DGL Meter
  • The moving coil, rectifier panel meters, DGL 48/72/96/144 housed in moulded polycarbonate cases are suitable for the measurement of AC currents and voltages.
  • Sigma Series FML Meter
  • The pointer type frequency meters, FML 96 and FML 144 housed in moulded polycarbonate cases are used for the measurement of frequencies in the range of 45 to 450 Hz
  • Kappa Series
  • Kappa Series Shunts Provide an accurate DC millivolt signal to drive ammeter indicators, overload protection and control devices, especially for higher amperage. They Supply a voltage drop proportional to the DC current which is measured. The current passing through the shunt produces a proportional voltage drop. A moving coil instrument connected to shunt measures the voltage drop across the shunt terminals.
  • Sigma Series LFL Meter
  • The moving coil indicators LFL 96/144 and a phase angle adjuster are used to monitor changing power factor conditions on irreversible balanced load systems.
  • Sigma Series LML Meter
  • These instruments are suitable to indicate forward (export / out going) and reverse (import/in coming) power flow as well as inductive and capacitive reactive power.
  • Sigma Series EQC Meter
  • This meter offers several advantages in switchboards and transformers Panels, used for measurement of electrical parameters along with the threshold settings for relay operation.
  • Sigma Series Elapsed Time Meter
  • Elapsed Time Meters ETM 72/96 housed in moulded polycarbonate cases are suitable for the measurement of run time of machines, equipments and other devices.
  • Sigma Series FQ Meter
  • The reed type frequency meters, FQ 72 / 96 housed in moulded polycarbonate cases are suitable for the measurement of these instrument offer several advantages in switchboard and Generating Set Panels. Number of meters can be mounted in a single Cut out (Mosaic mounting). Front glass, Bezel & Dial can frequencies in the range of 45 to 65 Hz. be easily replaced.
  • Sigma Series PQC Meter
  • This meter measure average DC Voltage and current. This meter is used for measurement as well as for protection having two sets of relay contacts & scale interchangeability feature and housed in UL 94 V-0 approved polycarbonate case and can be mounted in Mosaic mounting (cascading).
  • Sigma Series LM Meter
  • These instruments are suitable to indicate forward (export / out going) and reverse (import / in coming) power flow.
  • Sigma Series FM Meter
  • The pointer type frequency meters, FM 48/ 72 / 96 / 144 housed in moulded polycarbonate cases are suitable for the measurement of frequencies in the range of 45 to 450 Hz
  • Sigma Series LF Meter
  • The moving coil indicators and a phase angle adjuster are used to monitor changing power factor conditions on ir-reversible balanced load systems
  • Sigma Series DE 2 IN 1 Meter
  • DE 2 in 1 The moving iron panel meters are housed in moulded polycarbonate cases and are suitable for the measurement of AC currents for frequency range of 15...400Hz and voltages in the frequency range of 15...100Hz
  • Sigma Series DS 2 IN 1 Meter
  • The moving iron panel meters, 2 in 1 housed in moulded polycarbonate cases are suitable for the measurement of DC currents for frequency range of 15...400Hz and voltages in the frequency range of 15...100Hz
  • Sigma Series FM 2 IN 1 Meter
  • The pointer type frequency meters ,2 in 1 FM 96 housed in moulded polycarbonate cases are suitable for the measurement of frequencies in the range of 45 to 450 Hz
  • Selector Switch Meter
  • The moving iron, panel meters, EQ 72/96 housed in moulded polycarbonate cases are suitable for the measurement of AC currents for frequency range of 15...400Hz and voltages in the frequency range of 15...100Hz
  • Sigma Series EB-BM Meter
  • The maximum demand ammeters BM 48 and BM/EB 72/96 housed inmoulded polycarbonate cases,monitor the most economic use of transformer stations & LT distribution feeders by indicating the thermal/time characteristics of the load.
  • Sigma Series DE,DS,FM-35 Meter
  • The analog DE 35, DS 35, FM 35 meters, designed for the measurement of current, voltage & frequency in distribution, installations which utilizes 35 mm. DIN rails for equipment mounting. The mounting width is 45 mm